Membrane

 
TECHNICAL INFORMATION
  Performance Testing condition
Type Average rejection rate Average Permeate flow GPD(m3/d) Active membrane area ft2(m2) Testing pressure Temperature of testing solution Concentration of testing solution PH rate of testing solution Recovery rate of single membrane elements
50GPD 97.5% 50(0.19) 3.5(0.32) 60psi
(0.41Mpa)
25°C 500ppm 7.5 15%
75GPD 97.5% 75(0.28) 4.0(0.37)
100GPD 97.5% 100(0.38) 5.0(0.46)
300GPD 96% 300(1.14) 14.4(1.35) 90psi (0.61Mpa) 25°C 500ppm 7.5 15%
 
  • Membrane material: Polyamide
  • Max operation temperature: 45°
  • Max operation pressure: 300psi (2.07Mpa)
  • PH rate range of feedwater as continuous operations: 3-10
  • PH rate range of feedwater as chemical cleaning: 2-11
  • Max feedwater SDI: 5
  • Acceptance capacity of free chlorine: < 0.1ppm
 

Industrial Membrane

TECHNICAL INFORMATION
  Performance Testing condition
Type Average rejection rate Average Permeate flow GPD(m3/d) Active membrane area ft2(m2) Testing pressure Temperature of testing solution Concentration of testing solution PH rate of testing solution Recovery rate of single membrane elements
4040 99.2% 2000(8.4) 80(7.5) 150psi (1.O5Mpa) 25°C 1500ppm   15%
8040 99.2% 9500(36) 385(36.0)
 
  • Membrane material: Polyamide
  • Max pressure difference: 13psi (0.09 Mpa)
  • PH rate range of feedwater as continuous operations: 2-11
  • PH rate range of feedwater as chemical cleaning: 1-12
  • Max feedwater SDI: 5
  • Acceptance capacity of free chlorine: < 0.1ppm
  • The minimal proportion of concentrated water flow and permeate flow: 5:1
 
Membrane
Membrane
Membrane
 

Membrane Housing

TYPE

Single O-ring and double O-ring use for 50GPD, 75 GPD and 100GPD membranes


SPECIFICATION
  • Port: ¼" NPT
  • Working Temp.: 1.5 ˜ 45°C
  • Harmer Capacity: 100,000 times
  • Bursting Pressure: 507psi
 
H-10 Membrane
H-10 Membrane
Double O NW BR107
Double O NW BR107